BL-1021
Message
<timestamp>, [BL-1021], <sequence-number>,, INFO, <system-name>,
Retry <Retry Number>, internal port retry initialization, <List of
internal ports retrying initialization>
Probable
Indicates that the switch had internal ports not online and that the system is retrying to bring the ports
Cause
that failed back online.
Recommended
No action is required.
Action
Severity
INFO
BL-1022
Message
<timestamp>, [BL-1022], <sequence-number>,, CRITICAL, <system-
name>, Init Failed: Switch DISABLED because internal ports were not
ONLINE, <list of internal port number not ONLINE>
Probable
Indicates that the switch initiation failed because one or more of the internal ports was not online. The
Cause
switch is faulted.
Recommended
Reboot or power cycle the switch.
Action
Run the systemVerification command to verify that the switch does not have hardware problems. Refer
to the Fabric OS Command Reference for more information on this command.
Additional fault messages precede and follow this error, providing more information. See other error
messages for recommended action.
If the message persists, replace the switch.
Severity
CRITICAL
BL-1023
Message
<timestamp>, [BL-1023], <sequence-number>,, CRITICAL, <system-
name>, Blade in slot <slot number> was reset before blade init
completed. As a result the blade is faulted.
Probable
Indicates that the blade was reset before the initialization completed.
Cause
Fabric OS Message Reference