PDM System Messages
PDM-1001
Message
<timestamp>, [PDM-1001], <sequence-number>,, WARNING, <system-
name>, Failed to parse the pdm config
Probable
Indicates that the PDM process could not parse the configuration file. This might be caused by a
Cause
missing configuration file during the installation.
Recommended
Run the firmwareDownload command to reinstall the firmware.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
PDM-1002
Message
<timestamp>, [PDM-1002], <sequence-number>,, WARNING, <system-
name>, ipcInit failed
Probable
Indicates that the PDM process could not initialize the IPC mechanism.
Cause
Recommended
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
Action
supportSave command and contact your switch service provider.
Severity
WARNING
PDM-1003
Message
<timestamp>, [PDM-1003], <sequence-number>,, WARNING, <system-
name>, pdm [-d] -S <service> -s <instance>