Severity
CRITICAL
EM-1011
Message
<timestamp>, [EM-1011], <sequence-number>, FFDC, CRITICAL, <system-
name>, Received unexpected power down for <FRU Id>, but cannot
determine if it has power
Probable
Indicates that the environmental monitor (EM) received an unexpected power-down notification from
Cause
the FRU specified; however, after four seconds it cannot be determined if it has powered down or not.
Recommended
Try reseating the blade. If this fails to correct the error, replace the blade.
Action
Severity
CRITICAL
EM-1012
Message
<timestamp>, [EM-1012], <sequence-number>, FFDC, CRITICAL, <system-
name>, <FRU Id> failed <state> state transition, FRU faulted
Probable
Indicates that a switch blade or nonbladed switch failed to transition from one state to another. It is
Cause
faulted. The specific failed target state is displayed in the message. There are serious internal Fabric OS
configuration or hardware problems on the switch.
Recommended
On SilkWorm 24000 and 48000, try reseating the indicated FRU.
Action
If the message persists, reboot or power cycle the switch.
Run the systemVerification command to verify that the switch does not have hardware problems. Refer
to the Fabric OS Command Reference for more information on this command.
If the message persists, replace the FRU.
Severity
CRITICAL
EM-1013
Message
<timestamp>, [EM-1013], <sequence-number>,, ERROR, <system-name>,
Failed to update FRU information for <FRU Id>
Probable
Indicates that the environmental monitor was unable to update the time alive or OEM data in the
Cause
memory on a FRU.