Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 186

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

18
FCR-1060
Probable
Indicates that the DH-CHAP authentication failed on the EX port.
Cause
Recommended
Verify that the shared secrets on both sides of the link match.
Action
Disable and enable the ports using the portDisable then portEnable commands to restart
authentication.
Severity
INFO
FCR-1060
Message
<timestamp>, [FCR-1060], <sequence-number>,, WARNING, <system-
name>, EX port(<port number>) has an incompatible configuration
setting.
Probable
Indicates that VC Link Init is enabled on the local switch and the remote switch is negotiating in
Cause
R_RDY mode. The fabric might not form properly.
Recommended
Check the configuration on the local switch using the portCfgShow command to verify that the VC
Action
Link Init is disabled, if the remote switch is configured in R_RDY mode or only capable of R_RDY
mode.
VC_RDY mode: Virtual-channel flow control mode. This is a proprietary protocol.
R_RDY mode: Receiver-ready flow control mode. This is the Fibre Channel standard protocol, that
uses R_RDY primitive for flow control.
Severity
WARNING
FCR-1061
Message
<timestamp>, [FCR-1061], <sequence-number>,, INFO, <system-name>,
Backbone fabric created on port <port number>.
Probable
Indicates that a backbone fabric was built on the specified port.
Cause
Recommended
No action is required.
Action
Severity
INFO
18-18
Fabric OS Message Reference
Publication Number: 53-1000242-01

Advertisement

Table of Contents
loading

Table of Contents