Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 124

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

9
EM-1008
For the SilkWorm 200E, 3016, 3250, 3850, 4100, and 4900 replace the switch.
Severity
CRITICAL
EM-1008
Message
<timestamp>, [EM-1008], <sequence-number>, FFDC, CRITICAL, <system-
name>, Unit in <FRU Id> faulted, incompatible with chassis option
<chassis configuration option>
Probable
Indicates that a blade inserted in the specified slot is not compatible with the switch chassisConfig
Cause
option. The blade is faulted.
Recommended
Replace the blade. Make sure the replacement blade is compatible with your CP type and chassisConfig
Action
setting.
Severity
CRITICAL
EM-1009
Message
<timestamp>, [EM-1009], <sequence-number>, FFDC, CRITICAL, <system-
name>, <FRU Id> powered down unexpectedly
Probable
Indicates that the environmental monitor (EM) received an unexpected power-down notification from
Cause
the specified FRU. This might indicate a hardware malfunction in the FRU.
Recommended
Try reseating the FRU. If the message persists, replace the FRU. Refer to the SilkWorm 48000
Action
Hardware Reference Manual for more information about chassisConfig modes and supported blades.
Severity
CRITICAL
EM-1010
Message
<timestamp>, [EM-1010], <sequence-number>, FFDC, CRITICAL, <system-
name>, Received unexpected power down for <FRU Id> But <FRU Id>
still has power
Probable
Indicates that the environmental monitor received an unexpected power-down notification from the
Cause
specified FRU. However, the specified FRU still appears to be powered up after four seconds.
Recommended
Try reseating the blade. If this fails to correct the error, replace the blade.
Action
9-4
Fabric OS Message Reference
Publication Number: 53-1000242-01

Advertisement

Table of Contents
loading

Table of Contents