Collect supportSave information, then reboot switch and run POST. If problem persists, replace switch.
Action
Severity
CRITICAL
BL-1027
Message
<timestamp>, [BL-1027], <sequence-number>,, CRITICAL, <system-
name>, Blade in slot <slot number> faulted, boot failed; status
0x<boot status> 0x<1250 0 boot status> 0x<1250 1 boot status>.
Probable
Indicates that the blade failed to boot properly.
Cause
Recommended
Reboot or power cycle the blade.
Action
If the message persists, replace the blade.
Severity
CRITICAL
BL-1028
Message
<timestamp>, [BL-1028], <sequence-number>,, CRITICAL, <system-
name>, Switch faulted; internal processor was reset before switch
init completed.
Probable
Indicates that the switch's internal processor was reset before the initialization completed.
Cause
Recommended
Reboot or power cycle the switch.
Action
If the message persists, replace the switch.
Severity
CRITICAL
BL-1029
Message
<timestamp>, [BL-1029], <sequence-number>,, INFO, <system-name>,
All ports on the switch will be reset as part of the firmware
upgrade.
Probable
Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded
Cause
and resulted in the cold upgrade. As part of the upgrade, all the datapath elements were reset.