9
EM-2003
Severity
CRITICAL
EM-2003
Message
<timestamp>, [EM-2003], <sequence-number>,, ERROR, <system-name>,
Slot <Slot Id> has failed the POST tests. FRU is being faulted.
Probable
Indicates that a FRU did not pass the Power On Self Tests. Please see the /tmp/post[1/2].slot#.log file
Cause
for more information on fault. The slot will be 0 for non-bladed systems.
Recommended
On bladed systems, try reseating the specified FRU.
Action
On nonbladed switches, reboot or power cycle the switch.
If the problem persists:
•
Run the systemVerification command to verify that the switch does not have hardware problems.
Refer to the Fabric OS Command Reference for more information on this command.
•
On bladed systems, replace the specified FRU, otherwise replace the switch
Severity
ERROR
9-18
Fabric OS Message Reference
Publication Number: 53-1000242-01