Message
<timestamp>, [SEC-1121], <sequence-number>,, ERROR, <system-name>,
Time is out of range when <text>.
Probable
Indicates that the time on the switch is not synchronized with the primary FCS, the data packet is
Cause
corrupted, or a replay attack is launched on the switch.
Recommended
Verify that the security event was planned. If the security event was planned, verify that all switches in
Action
the fabric are in time synchronization with the primary FCS and that no external entity is trying to
access the fabric. When verification is complete, retry the operation.
Severity
ERROR
SEC-1122
Message
<timestamp>, [SEC-1122], <sequence-number>,, INFO, <system-name>,
Error code: <Domain ID>, <Error message>.
Probable
Indicates that one of the switches in the fabric could not communicate with the primary FCS.
Cause
Recommended
Run the secFabricShow command to verify that all switches in fabric are in the ready state. When all
Action
switches are in the ready state, retry the operation.
Severity
INFO
SEC-1123
Message
<timestamp>, [SEC-1123], <sequence-number>,, INFO, <system-name>,
Security database downloaded by Primary FCS.
Probable
Indicates that the security database was successfully downloaded from the primary FCS.
Cause
Recommended
No action is required.
Action
Severity
INFO