LOG System Messages
LOG-1000
Message
<timestamp>, [LOG-1000], <sequence-number>,, INFO, <system-name>,
Previous message repeated <repeat count> time(s)
Probable
Indicates that the previous message repeated the specified number of times.
Cause
Recommended
No action is required.
Action
Severity
INFO
LOG-1001
Message
<timestamp>, [LOG-1001], <sequence-number>, FFDC, WARNING, <system-
name>, A log message was dropped
Probable
Indicates that a log message was dropped. A trace dump file is created.
Cause
Recommended
Run the reboot command for nonbladed switches or the haFailover command on bladed switches.
Action
Run the saveCore command to FTP core files to a server location. It is normal behavior if there are no
core files to transfer.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
Fabric OS Message Reference
Publication Number: 53-1000242-01
Chapter
39
39-1