AUTH System Messages
AUTH-1001
Message
<timestamp>, [AUTH-1001], <sequence-number>,, INFO, <system-name>,
<Operation type> has been successfully done.
Probable
Indicates that the secret database operation has been updated using the secAuthSecret command. The
Cause
values for Operation type can be "set" or "remove".
Recommended
No action is required.
Action
Severity
INFO
AUTH-1002
Message
<timestamp>, [AUTH-1002], <sequence-number>,, ERROR, <system-name>,
<Operation type> has failed.
Probable
Indicates that the specified action has failed to update the secret database using the secAuthSecret
Cause
command. The values for Operation type can be "set" or "remove".
Recommended
Retry the secAuthSecret command.
Action
Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command
and contact your switch service provider.
Severity
ERROR
AUTH-1003
Message
<timestamp>, [AUTH-1003], <sequence-number>,, INFO, <system-name>,
<data type> type has been successfully set to <setting value>.
Fabric OS Message Reference