5
BM-1009
Severity
WARNING
BM-1009
Message
<timestamp>, [BM-1009], <sequence-number>,, WARNING, <system-name>,
Firmwaredownload timed-out for application processor. Faulting
switch.
Probable
FirmwareDownload of the application processor failed.
Cause
Recommended
Power-cycle the switch.
Action
Severity
WARNING
BM-1054
Message
<timestamp>, [BM-1054], <sequence-number>,, INFO, <system-name>, AP
firmware <Blade firmware> is not consistent with system firmware
<System firmware>. Auto-leveling AP firmware to match system
firmware.
Probable
The policy of the specified blade is to auto-level the blade firmware to the system firmware, so either:
Cause
•
Blade firmware was detected to be different from CP firmware due to a firmware upgrade
•
The blade was just inserted and had a different firmware loaded
Recommended
No action is required, the blade will automatically download the updated firmware.
Action
Severity
INFO
BM-1055
Message
<timestamp>, [BM-1055], <sequence-number>,, WARNING, <system-name>,
Firmwaredownload timed-out for AP. Faulting switch.
Probable
FirmwareDownload of the AP failed.
Cause
Recommended
Power-cycle or reboot the switch.
Action
5-4
Fabric OS Message Reference
Publication Number: 53-1000242-01