Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 112

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

5
BM-1009
Severity
WARNING
BM-1009
Message
<timestamp>, [BM-1009], <sequence-number>,, WARNING, <system-name>,
Firmwaredownload timed-out for application processor. Faulting
switch.
Probable
FirmwareDownload of the application processor failed.
Cause
Recommended
Power-cycle the switch.
Action
Severity
WARNING
BM-1054
Message
<timestamp>, [BM-1054], <sequence-number>,, INFO, <system-name>, AP
firmware <Blade firmware> is not consistent with system firmware
<System firmware>. Auto-leveling AP firmware to match system
firmware.
Probable
The policy of the specified blade is to auto-level the blade firmware to the system firmware, so either:
Cause
Blade firmware was detected to be different from CP firmware due to a firmware upgrade
The blade was just inserted and had a different firmware loaded
Recommended
No action is required, the blade will automatically download the updated firmware.
Action
Severity
INFO
BM-1055
Message
<timestamp>, [BM-1055], <sequence-number>,, WARNING, <system-name>,
Firmwaredownload timed-out for AP. Faulting switch.
Probable
FirmwareDownload of the AP failed.
Cause
Recommended
Power-cycle or reboot the switch.
Action
5-4
Fabric OS Message Reference
Publication Number: 53-1000242-01

Advertisement

Table of Contents
loading

Table of Contents