RTWR System Messages
RTWR-1001
Message
<timestamp>, [RTWR-1001], <sequence-number>,, ERROR, <system-name>,
RTWR <routine: error message> 0x<detail 1>, 0x<detail 2>, 0x<detail
3>, 0x<detail 4>, 0x<detail 5>
Probable
Indicates that an error occurred in the RTWR. The message provides the name of the routine having the
Cause
error, and more specific error information. The values in details 1 through 5 might provide more
information.
Recommended
No action is required.
Action
Severity
ERROR
RTWR-1002
Message
<timestamp>, [RTWR-1002], <sequence-number>,, WARNING, <system-
name>, RTWR <error message> 0x<detail1>, 0x<detail2>, 0x<detail3>,
0x<detail4>, 0x<detail5>
Probable
Indicates that the RTWR has exhausted the maximum number of retries sending data to the specified
Cause
domain. Possible detail values include:
•
RTWRTransmit: Max retries exhausted
•
detail1: Port
•
detail2: Domain
•
detail3: Retry Count
•
detail4: Status
•
detail5: Process ID
Recommended
Run the fabricShow command to see if the specified domain ID is online.
Action
Enable the switch with the specified domain ID.
Fabric OS Message Reference
Publication Number: 53-1000242-01
Chapter
56
56-1