RTWR System Messages
RTWR-1001
Message
<timestamp>, [RTWR-1001], <sequence-number>,, ERROR, <system-name>,
RTWR <routine: error message> 0x<detail 1>, 0x<detail 2>, 0x<detail
3>, 0x<detail 4>, 0x<detail 5>
Probable
Indicates that an error occurred in the RTWR. The message provides the name of the routine having the
Cause
error, and more specific error information. The values in details 1 through 5 might provide more
information.
Recommended
No action is required.
Action
Severity
ERROR
RTWR-1002
Message
<timestamp>, [RTWR-1002], <sequence-number>,, WARNING, <system-
name>, RTWR <error message> 0x<detail1>, 0x<detail2>, 0x<detail3>,
0x<detail4>, 0x<detail5>
Probable
Indicates that the RTWR has exhausted the maximum number of retries sending data to the specified
Cause
domain. Possible detail values include:
RTWRTransmit: Max retries exhausted
detail1: Port
detail2: Domain
detail3: Retry Count
detail4: Status
detail5: Process ID
Recommended
Run the fabricShow command to see if the specified domain ID is online.
Action
Enable the switch with the specified domain ID.