Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 98

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

3
BL-1014
Recommended
Make sure to capture the console output during this process.
Action
Check for a faulty cable, SFP, or device attached to the specified port.
On a bladed switch, run the slotPowerOff and slotPowerOn commands.
On a nonbladed switch, reboot or power cycle the switch.
If the message persists, replace the blade.
Severity
ERROR
BL-1014
Message
<timestamp>, [BL-1014], <sequence-number>,, ERROR, <system-name>,
bport <port number> port int. is disabled. status=0x<interrupt
status>
Probable
Indicates that the port generated an excessive number of interrupts that might prove fatal to the switch
Cause
operation. The port is disabled to prevent the CP from becoming too busy. The bport is the blade port;
this number might not correspond to a user port number.
Recommended
Make sure to capture the console output during this process.
Action
On a bladed switch, run the slotPowerOff and slotPowerOn commands.
On a nonbladed switch, reboot the switch.
Run the systemVerification command to determine if there is a hardware error.
If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors
are encountered again:
On the SilkWorm 12000, 24000, and 48000, replace the blade FRU.
On the SilkWorm 3900, replace the motherboard FRU.
On the SilkWorm 200E, 3016, 3250, 3850, or 4100, replace the switch.
Severity
ERROR
BL-1015
Message
<timestamp>, [BL-1015], <sequence-number>,, ERROR, <system-name>,
bport <port number> port is faulted. status=0x<interrupt status>
Probable
Indicates that the port generated an excessive number of interrupts that might prove fatal to the switch
Cause
operation. The port is disabled to prevent the CP from becoming too busy. The bport is the blade port;
this number might not correspond to a user port number.
Recommended
Make sure to capture the console output during this process.
Action
3-6
Fabric OS Message Reference
Publication Number: 53-1000242-01

Advertisement

Table of Contents
loading