EM-1055
Message
<timestamp>, [EM-1055], <sequence-number>,, WARNING, <system-name>,
<FRU Id>: Port media incompatible. Reason: <Reason for
incompatibility>
Probable
Indicates that an incompatible port media is detected.
Cause
The possible causes are:
The port media is not capable of running at the configured port speed.
The port media generates too much heat to be used in the slot.
Recommended
Verify that the media can be run at the configured port speed.
Action
If the port media is extended long wavelength, move it to a port that can support the heat generated.
Severity
WARNING
EM-1056
Message
<timestamp>, [EM-1056], <sequence-number>,, WARNING, <system-name>,
<FRU Id>: Port faulted. Reason: <Reason code for the fault>
Probable
Indicates a faulty port media is detected. The reason code for this message is for internal use only. This
Cause
message is valid for only the SilkWorm 4100 and 4900.
Recommended
Replace the defective SFP.
Action
Severity
WARNING
EM-1057
Message
<timestamp>, [EM-1057], <sequence-number>,, WARNING, <system-name>,
Blade:<Slot Id> is getting reset:<Fault reason>
Probable
The switch is automatically reset due to known resetable transient errors, such as bloom parity. error.
Cause
Recommended
No action is required if the switch does not reach the reset threshold for the switch/blade. If the reset
Action
threshold is reached on the switch/blade, the switch/blade will be faulted and should be replaced.
Severity
WARNING