Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 280

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

25
FW-1376
Probable
Indicates that the number of incompatible security database violations has changed from a value outside
Cause
of the acceptable range to a value within the acceptable range. This violation indicates the number of
secure switches with different version stamps have been detected. When a switch is in secure mode, it
connects only to another switch that is in secure mode and has a compatible security database. A
compatible security database means that the version stamp and FCS policy matches exactly.
Recommended
No action is required.
Action
Severity
INFO
FW-1376
Message
<timestamp>, [FW-1376], <sequence-number>,, INFO, <system-name>,
<Label>, value has changed(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
Probable
Indicates that the number of illegal commands has changed. This counter tracks how many times
Cause
commands allowed only on the primary FCS switch have been executed on a non-primary FCS switch.
There are many commands that can be executed only on the primary FCS switch as well as one security
command that can be executed only on a backup FCS switch. The counter increments every time
someone issues one of these commands on a switch where it is not allowed.
Recommended
Responses to security-class messages depend on user policies. Consult your security administrator for
Action
response strategies and policies.
Severity
INFO
FW-1377
Message
<timestamp>, [FW-1377], <sequence-number>,, INFO, <system-name>,
<Label>, is below low boundary(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
Probable
Indicates that the number of illegal commands has fallen below the low boundary. This counter tracks
Cause
how many times commands allowed only on the primary FCS switch have been executed on a non-
primary FCS switch. There are many commands that can be executed only on the primary FCS switch
as well as one security command that can be executed only on a backup FCS switch. The counter
increments every time someone issues one of these commands on a switch where it is not allowed.
Recommended
No action is required.
Action
Severity
INFO
25-74
Fabric OS Message Reference
Publication Number: 53-1000242-01

Advertisement

Table of Contents
loading

Table of Contents