SCN System Messages
SCN-1001
Message
<timestamp>, [SCN-1001], <sequence-number>, FFDC, CRITICAL,
<system-name>, SCN queue overflow for process <daemon name>
Probable
Indicates that an attempt to write an SCN (state change notification) message to a specific queue has
Cause
failed because the SCN queue for the specified daemon name is full. This might be caused by the
daemon hanging or if the system is busy.
The valid values for daemon name are:
fabricd
asd
evmd
fcpd
webd
msd
nsd
psd
snmpd
zoned
fspfd
tsd
Recommended
If this message is caused by the system being busy, the condition is temporary.
Action
If this message is caused by a hung daemon, the software watchdog will cause the daemon to dump the
core and reboot the switch. In this case, run the saveCore command to send the core files using FTP to
a secure server location.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
CRITICAL
Fabric OS Message Reference
Publication Number: 53-1000242-01
Chapter
57
57-1