Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 129

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

EM-1031
Message
<timestamp>, [EM-1031], <sequence-number>,, ERROR, <system-name>,
<FRU Id> ejector not closed
Probable
Indicates that the environmental monitor (EM) has found a switch blade that is inserted, but the ejector
Cause
switch is not closed. The blade in the specified slot is treated as not inserted.
Recommended
Close the ejector switch (raise the slider in most blades, or completely screw in the upper thumbscrew
Action
for the FC4-48 port blade) if the FRU is intended for use. Refer to the appropriate hardware manual for
instructions on inserting the switch blades.
Severity
ERROR
EM-1033
Message
<timestamp>, [EM-1033], <sequence-number>,, ERROR, <system-name>,
CP in <FRU Id> set to faulty because CP ERROR asserted
Probable
Indicates that the standby CP has been detected as faulty. The High Availability feature will not be
Cause
available. This message occurs every time the other CP reboots, even as part of a clean warm failover.
In most situations, this message is followed by the EM-1047 message, and no action is required for the
CP; however, you might want to find out why the failover occurred.
Recommended
If the standby CP was just rebooted, wait for the error to clear (run slotShow to determine if it has
Action
cleared). Watch for the EM-1047 message to verify this error cleared.
If the standby CP continues to be faulty or if it was not intentionally rebooted, check the error logs on
the other CP (using the errDump command) to determine the cause of the error state.
Try reseating the FRU. If the message persists, replace the FRU.
Severity
ERROR
EM-1034
Message
<timestamp>, [EM-1034], <sequence-number>,, ERROR, <system-name>,
<FRU Id> set to faulty, rc=<return code>
Probable
Indicates that the specified FRU has been marked as faulty for the specified reason.
Cause
Recommended
Try reseating the FRU.
Action
Fabric OS Message Reference
Publication Number: 53-1000242-01
9