39
LOG-1002
LOG-1002
Message
<timestamp>, [LOG-1002], <sequence-number>, FFDC, WARNING, <system-
name>, A log message was dropped
Probable
Indicates that a message was not recorded by the error logging system. A trace dump file is created. The
Cause
message might still be visible through SNMP or other management tools.
Recommended
Run the reboot command for nonbladed switches or the haFailover command on bladed switches.
Action
Run the saveCore command to FTP core files to a server location. It is normal behavior if there are no
core files to transfer.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
LOG-1003
Message
<timestamp>, [LOG-1003], <sequence-number>,, INFO, <system-name>,
The log has been cleared.
Probable
Indicates that the persistent error log has been cleared.
Cause
Recommended
No action is required.
Action
Severity
INFO