Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 178

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

18
FCR-1029
FCR-1029
Message
<timestamp>, [FCR-1029], <sequence-number>,, INFO, <system-name>,
Port WWN pool 95 percent allocated.
Probable
Indicates that the Port WWN pool has rolled over and WWN entries detected to not be in use are reused
Cause
as needed.
Recommended
It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in
Action
a very large MetaSAN environment with large number of LSAN devices and fabrics, or there are highly
dynamic changes to EX port connectivity. WWN conflicts might cause unpredictable behavior in
management applications.
To avoid WWN conflicts, all EX ports attached to fabrics with highly dynamic changes to EX port
connectivity should be disabled then reenabled.
Severity
INFO
FCR-1030
Message
<timestamp>, [FCR-1030], <sequence-number>,, INFO, <system-name>,
Physical device <device WWN> came online at fabric <fabric ID>.
Probable
Indicates that the physical device WWN came online in the specified fabric.
Cause
Recommended
No action is required.
Action
Severity
INFO
FCR-1031
Message
<timestamp>, [FCR-1031], <sequence-number>,, INFO, <system-name>,
Physical device <device WWN> went offline in fabric <fabric ID>.
Probable
Indicates that the physical device WWN went offline in the specified fabric.
Cause
Recommended
No action is required.
Action
Severity
INFO
18-10
Fabric OS Message Reference