64
SYSM-1003
SYSM-1003
Message
<timestamp>, [SYSM-1003], <sequence-number>,, INFO, <system-name>,
<number>, Switch: <start reason>
Probable
Indicates that the user executed the switchStart or switchReboot command. This indicates that all
Cause
services are brought back up after a temporary shutdown of that logical switch.
Recommended
No action is required if the switchStart command was executed intentionally. Because reinitializing a
Action
switch is a disruptive operation and can stop I/O traffic, you might have to stop and restart the traffic
during this process.
Severity
INFO
SYSM-1004
Message
<timestamp>, [SYSM-1004], <sequence-number>,, ERROR, <system-name>,
Failed to retrieve current chassis configuration option,
ret=<Unknown>
Probable
Indicates that there was a failure to read configuration data from the WWN card.
Cause
Recommended
Verify that the WWN card is present and operational and that the affected CP is properly seated in its
Action
slot.
Severity
ERROR
SYSM-1005
Message
<timestamp>, [SYSM-1005], <sequence-number>, FFDC, CRITICAL,
<system-name>, CP blade in slot <Slot number> failed to retrieve
current chassis type.
Probable
Indicates that there was a failure to read the chassis type from the system.
Cause
Recommended
Verify that the CP blade is operational and is properly seated in its slot.
Action
Severity
CRITICAL