EM-1037
Message
<timestamp>, [EM-1037], <sequence-number>,, INFO, <system-name>,
<FRU Id> is no longer faulted.
Probable
Indicates that the specified Power Supply has been marked as no longer being faulty. Probably because
Cause
its AC power supply has been turned on.
Recommended
No action is required.
Action
Severity
INFO
EM-1041
Message
<timestamp>, [EM-1041], <sequence-number>,, WARNING, <system-name>,
Sensor values for <FRU Id>: <Sensor Value> <Sensor Value> <Sensor
Value> <Sensor Value> <Sensor Value> <Sensor Value> <Sensor Value>
Probable
Indicates that sensors detected a warning condition. All significant sensors for the FRU are displayed;
Cause
each contains a header.
This message can display:
voltages in volts
temperature in Celsius
fan speeds in RPM
Recommended
If the message is isolated, monitor the error messages on the switch. If the message is associated with
Action
other messages, follow the recommended action for those messages.
Severity
WARNING
EM-1042
Message
<timestamp>, [EM-1042], <sequence-number>,, WARNING, <system-name>,
Important FRU header data for <FRU Id> is not valid).
Probable
Indicates that the indicated FRU has an incorrect number of sensors in its FRU header-derived
Cause
information. This could mean that the FRU header was corrupted or read incorrectly or corrupted in the
object database, which contains information about all FRUs.
Recommended
Try reseating the FRU. If the message persists, replace the FRU.