3
BL-1030
Recommended
No action is required.
Action
Severity
INFO
BL-1030
Message
<timestamp>, [BL-1030], <sequence-number>,, INFO, <system-name>,
All GigE/FCIP ports on the switch will be reset as part of the
firmware upgrade.
Probable
Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded
Cause
and resulted in the cold upgrade. As part of the upgrade, all the GigE/FCIP data elements were reset.
Recommended
No action is required.
Action
Severity
INFO
BL-1031
Message
<timestamp>, [BL-1031], <sequence-number>,, CRITICAL, <system-
name>, Link timeout in internal port (slot <Slot number>, port <Port
number>) resulted in blade fault. Use slotpoweroff/slotpoweron to
recover the blade
Probable
Indicates that link timeout occurred in one of the backend internal ports.
Cause
Recommended
Power cycle the blade or run the slotPowerOff and slotPowerOn commands.
Action
Severity
CRITICAL
BL-1032
Message
<timestamp>, [BL-1032], <sequence-number>,, CRITICAL, <system-
name>, (slot <slot number>,bitmap 0x<object control flags(bitmap)>)
ports never came up ONLINE (reason <reason for port disable>, state
<status of the blade>). Disabling Slot.
3-12
Fabric OS Message Reference
Publication Number: 53-1000242-01