FCPD System Messages
FCPD-1001
Message
<timestamp>, [FCPD-1001], <sequence-number>,, WARNING, <system-
name>, Probing failed on <error string>
Probable
Indicates that an FCP switch probed devices on a loop port, and the probing failed on the either the
Cause
L_Port, AL_PA address, or the F_Port. For the AL_PA, the valid range is 00 through FF. The error sting
can be either:
L_Port port_number ALPA alpa_number
F_Port port_number
Recommended
This can happen when the firmware on the device controller on the specified port has a defect. Check
Action
with the device vendor for a firmware upgrade containing a defect fix.
The SilkWorm 4100 does not support private loop devices.
Severity
WARNING
FCPD-1002
Message
<timestamp>, [FCPD-1002], <sequence-number>,, WARNING, <system-
name>, port <port number>, bad R_CTL for fcp probing: 0x<R_CTL
value>
Probable
Indicates that the response frame received on the specified port for a inquiry request contains an invalid
Cause
value in the routing control field.
Recommended
This can happen only if the firmware on the device controller on the specified port has a defect. Check
Action
with the device vendor for a firmware upgrade containing a defect fix.