SYSM System Messages
SYSM-1001
Message
<timestamp>, [SYSM-1001], <sequence-number>, FFDC, CRITICAL,
<system-name>, No memory
Probable
Indicates that the switch has run out of system memory.
Cause
Recommended
Run the memShow command to view the switch memory usage.
Action
Reboot or power cycle the switch.
Run supportFtp and traceFtp (as needed) to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.
Severity
CRITICAL
SYSM-1002
Message
<timestamp>, [SYSM-1002], <sequence-number>,, INFO, <system-name>,
<number>, Switch: <Switch number>
Probable
Indicates that a user has executed either the switchShutdown or switchReboot command. All services
Cause
are brought down for a logical switch.
Recommended
No action is required if the switchShutdown or switchReboot command was executed intentionally. If
Action
the switchShutdown command was run, you must run the switchStart command to restart traffic on
the logical switch.
Severity
INFO