PLAT System Messages
PLAT-1000
Message
<timestamp>, [PLAT-1000], <sequence-number>, FFDC, CRITICAL,
<system-name>, <Function name> <Error string>
Probable
Indicates that nonrecoverable PCI errors have been detected.
Cause
Recommended
The system will be faulted and might automatically reboot.
Action
If the system does not reboot, then try issuing the reboot command from a command-line prompt.
Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command
and contact your switch service provider.
Severity
CRITICAL
PLAT-1001
Message
<timestamp>, [PLAT-1001], <sequence-number>,, INFO, <system-name>,
Resetting standby CP (double reset may occur)
Probable
Indicates that the standby CP is being reset. This message is typically generated by a CP that is in the
Cause
process of becoming the active CP. Note that in certain circumstances a CP may experience a double
reset and reboot twice in a row. A CP can recover automatically even if it has rebooted twice.
Recommended
No action is required.
Action
Severity
INFO