Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 185

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

Recommended
No action is required if backbone to edge routing is not needed. Otherwise replace the switch with one
Action
that supports backbone to edge routing.
Severity
INFO
FCR-1057
Message
<timestamp>, [FCR-1057], <sequence-number>,, ERROR, <system-name>,
EX port(<port number>) incompatible long distance parameters on
link.
Probable
Indicates that the port, which is configured in long distance mode, has incompatible long distance
Cause
parameters.
Recommended
Check the port configuration on both sides of the link using the portCfgShow command.
Action
Investigate the other switch for more details. Run the errShow command on the other switch to view
the error log for additional messages.
Severity
ERROR
FCR-1058
Message
<timestamp>, [FCR-1058], <sequence-number>,, WARNING, <system-
name>, Port <port number> isolated due to mismatched configuration
parameter; <segmentation reason>.
Probable
Indicates that the specified port was isolated after segmentation, which was caused by mismatched
Cause
configuration parameters.
Recommended
Please check the switches on both ends of the link for a possible mismatch in switch or port
Action
configuration parameters such as 'Operating Mode', EDTOV, or RATOV.
Run the portCfgExport command to modify the appropriate parameters on the local switch.
Run the appropriate configuration command to modify the switch or port parameters on the remote
switch.
Severity
WARNING
FCR-1059
Message
<timestamp>, [FCR-1059], <sequence-number>,, INFO, <system-name>,
EX port <port number> was disabled due to an authentication failure.
Fabric OS Message Reference
Publication Number: 53-1000242-01
18
FCR-1057
18-17