Run the slotShow command. If the blade is in a Faulty state, run the slotPowerOff and slotPowerOn
Action
commands to that blade to trigger another firmwareDownload. If the blade is stuck in LOADING state,
you need to remove and re-insert the blade to trigger another firmwareDownload. If the problem
persists, contact your switch service provider.
Severity
ERROR
SULB-1018
Message
AUDIT, <timestamp>, [SULB-1018], ERROR, FIRMWARE, <event-initiator-
details>, <event-location>, , Firmwaredownload timed out in slot
<Slot number>.
Probable
The error can be caused by unexpected disruption of firmwareDownload command, for example,
Cause
powering off of the indicated BP blade in the middle of firmwareDownload. This error can also be
caused by the persistent storage failure, or other hardware failures of the BP blade.
Recommended
Run the slotShow command. If the blade in in Faulty state, run the slotPowerOff and slotPowerOn
Action
commands to that blade to trigger another firmwareDownload. If the blade is stuck in LOADING state,
you need to remove and re-insert the blade to trigger another firmwareDownload. If the problem
persists, contact your switch service provider.
Severity
ERROR
SULB-1020
Message
AUDIT, <timestamp>, [SULB-1020], ERROR, FIRMWARE, <event-initiator-
details>, <event-location>, , New firmware failed to boot in slot
<Slot number>.
Probable
The BP blade should reboot with the new image. However, it is still running the old image. This error
Cause
can be caused because that new image has not been loaded properly to the indicated blade.
Recommended
Run the slotShow command. If the blade is in Faulty state, run the slotPowerOff and slotPowerOn
Action
commands to that blade to trigger another firmwareDownload. If the blade is stuck in LOADING state,
you need to remove and re-insert the blade to trigger another firmwareDownload. If the problem
persists, contact your switch service provider.
Severity
ERROR
79-10
Fabric OS Message Reference
Publication Number: 53-1000242-01