BLL System Messages
BLL-1000
Message
<timestamp>, [BLL-1000], <sequence-number>, FFDC, CRITICAL,
<system-name>, ASIC driver detected Slot <slot number> port <port
number> as faulty (reason: <reason>)
Probable
Indicates that a blade regulation problem was reported on the specified slot number. The blade is
Cause
faulted. All blade register fault codes are associated with BLOOM error messages. This message is
always paired with a BLOOM message that provides more information on the specific error. This
message occurs on only the SilkWorm 12000, 24000, and 48000.
The possible reason codes are as follows:
•
1 = Available buffer overflow
•
2 = Backend port buffer timeout
•
3 = Backend port got shut down
•
4 = Embedded port buffer timeout
•
5 = Excessive busy mini buffer
•
6 = Excessive RCC VC on E_Port
•
7 = Excessive RCC VC on FL_Port
•
8 = Fail detection buffer tag error
•
9 = Fail detection TX parity error
•
10 = EPI CMEM interrupt error
•
11 = CMI interrupt error
•
12 = Interrupt overrun
•
13 = FDET interrupt
•
14 = Interrupt suspended
•
15 = Filter LISTD error
•
16 = Unknown filter LIST error
•
17 = Wait for LPC open state
•
18 = Wait for Old port state
•
19 = Wait for Open init state
•
20 = TX parity error
Fabric OS Message Reference
Publication Number: 53-1000242-01
Chapter
4
4-1