SWCH-1006
Message
<timestamp>, [SWCH-1006], <sequence-number>,, WARNING, <system-
name>, HA state out of sync: Standby CP (ver = <standby SWC
version>) does not support NPIV functionality. (active ver =
<active SWC version>, NPIV devices = <'1' if NPIV devices exist;
Otherwise '0'. >)
Probable
Indicates that the standby CP does not support NPIV functionality and the switch has some NPIV
Cause
devices logged into the fabric.
Recommended
Load a firmware version on standby that supports NPIV functionality, using the firmwareDownload
Action
command.
Severity
WARNING
SWCH-1007
Message
<timestamp>, [SWCH-1007], <sequence-number>,, WARNING, <system-
name>, Switch port <port number> disabled due to \"<disable
reason>\".
Probable
Indicates that the switch port is disabled due to the reason displayed in the message.
Cause
Recommended
Based on the disable reason displayed, proper corrective action may to be required to restore the port.
Action
If insufficient frame buffers is the disable reason, reduce the distance or speed settings for the port to
reduce the buffer requirement of the link. Alternatively, one or more ports in the port group must be
disabled to make more buffers available for the link.
Please refer to the Fabric OS Administrator's Guide for more information about buffers.
Severity
WARNING
SWCH-1008
Message
<timestamp>, [SWCH-1008], <sequence-number>,, WARNING, <system-
name>, <area string> are port swapped on ports that do not support
port swap. Slot <slot number> will be faulted.
Probable
Indicates that the blade is enabled with the port configuration that already has already area swapped.
Cause
Fabric OS Message Reference
Publication Number: 53-1000242-01
62