FICU System Messages
FICU-1001
Message
<timestamp>, [FICU-1001], <sequence-number>,, ERROR, <system-name>,
<function name>: config<config Set(key)|Get(key)| Save> failed rc =
<error>
Probable
Indicates that one of the configuration management functions failed. The key variable is part of the
Cause
Fabric OS configuration database and is for support use only. The error variable is an internal error
number.
Recommended
Execute an haFailover on the switch if it has redundant CPs or reboot the switch. Run the saveCore
Action
command to check if your flash is full. If the flash is full, run the saveCore command to clear the core
files. Refer to the Fabric OS Command Reference for more information on these commands.
Severity
ERROR
FICU-1002
Message
<timestamp>, [FICU-1002], <sequence-number>,, ERROR, <system-name>,
Failed to get RNID from Management Server Domain=<domain>
rc=<error>
Probable
Indicates that the FICON-CUP daemon failed to get switch RNID from the management server due to a
Cause
Fabric OS problem. The domain variable displays the domain ID of the target switch for this RNID. The
error variable is an internal error number.
Recommended
If this is a bladed switch, execute the haFailover command. If the problem persists, or if this is a
Action
nonbladed switch, download a new firmware version using the firmwareDownload command. Refer to
the Fabric OS Command Reference for more information on this command.
Severity
ERROR
Fabric OS Message Reference