34
IPS-1004
Probable
Indicates that memory resources are low. This might be a transient problem.
Cause
Recommended
If the message persists, check the memory usage on the switch, using the memShow command.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
IPS-1004
Message
<timestamp>, [IPS-1004], <sequence-number>,, WARNING, <system-
name>, Port Config Mode Mismatch slot (<slot>) port(ge<port>):
current mode is (<current mode>)
Probable
Indicates that configured Port Mode is different from intended use.
Cause
Recommended
Change the port configuration (by deleting configured FCIP tunnels or iSCSI sessions) to return the port
Action
mode to neutral before attempting to configure the port for a different mode or use.
Severity
WARNING
IPS-1005
Message
<timestamp>, [IPS-1005], <sequence-number>,, WARNING, <system-
name>, Tunnel Authorization Failure for slot (<slot>)
port(ge<port>) tunnel ID(<tunnel number>) reason (<reason>)
Probable
Indicates that tunnel setup failed due to authorization failure from the remote side. Reasons for such
Cause
failures could be a WWN Mismatch.
Recommended
Change the tunnel configuration on one side of the tunnel to authorize remote side to setup tunnel.
Action
Severity
WARNING
IPS-1006
Message
<timestamp>, [IPS-1006], <sequence-number>,, WARNING, <system-
name>, Tunnel Configuration Mismatch for slot (<slot>) port(<port>)
tunnel ID(<tunnel number>) reason (<reason>)
34-2