MFIC System Messages
MFIC-1001
Message
<timestamp>, [MFIC-1001], <sequence-number>,, ERROR, <system-name>,
failure at sysmod_scn registry rc= <failure reason>
Probable
Indicates that the system is temporarily out of resources.
Cause
Recommended
No action is required; this message is often transitory.
Action
If the message persists, run a switch reboot or an haFailover (if applicable).
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
ERROR
MFIC-1002
Message
<timestamp>, [MFIC-1002], <sequence-number>,, INFO, <system-name>,
Chassis FRU header not programmed for switch NID, using defaults
(applies only to FICON environments).
Probable
Indicates that custom switch node descriptor (NID) fields have not been programmed in nonvolatile
Cause
storage. The default values are used. The Switch NID is used only in the following SB ELS frames:
Request Node Identification Data (RNID) and Registered Link Incident Record (RLIR).
The use of SB-3 link incident registration and reporting is typically limited to FICON environments.
Recommended
No action is required if SB-3 link incident registration and reporting is not used by the host or if default
Action
values are desired for the switch node descriptor fields.
Severity
INFO
Fabric OS Message Reference
Publication Number: 53-1000242-01
Chapter
41
41-1