Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 384

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

54
RCS-1003
RCS-1003
Message
<timestamp>, [RCS-1003], <sequence-number>,, ERROR, <system-name>,
Failed to allocate memory: (<function name>)
Probable
Indicates that the specified RCS function failed to allocate memory.
Cause
Recommended
This message is usually transitory. Wait a few minutes and retry the command.
Action
Check memory usage on the switch using the memShow command.
Reboot or power cycle the switch.
Severity
ERROR
RCS-1004
Message
<timestamp>, [RCS-1004], <sequence-number>,, ERROR, <system-name>,
Application(<application name>) not registered.(<error string>)
Probable
Indicates that a specified application did not register with RCS.
Cause
Recommended
Run the haShow command to view the HA state.
Action
Run the haDisable and the haEnable commands.
Run the rcsInfoShow command to view RCS capability on the fabric. RCS is supported in Fabric OS
v2.6, v3.1 and greater, v4.1 and greater.
Run the firmwareDownload command to upgrade the firmware for any switches that do not support
RCS.
Severity
ERROR
RCS-1005
Message
<timestamp>, [RCS-1005], <sequence-number>,, INFO, <system-name>,
Phase <RCS phase>, <Application Name> Application returned <Reject
reason>, 0x<Reject code>.
Probable
Indicates that a receiving switch is rejecting an RCS phase.
Cause
54-2
Fabric OS Message Reference
Publication Number: 53-1000242-01

Advertisement

Table of Contents
loading

Table of Contents