28
HIL-1404
HIL-1404
Message
<timestamp>, [HIL-1404], <sequence-number>,, WARNING, <system-
name>, <count> fan FRU(s) missing. Install fan FRU(s) immediately.
Probable
Indicates that one or more fan FRUs have been removed.
Cause
Recommended
Install the missing fan FRUs immediately.
Action
Severity
WARNING
HIL-1501
Message
<timestamp>, [HIL-1501], <sequence-number>,, WARNING, <system-
name>, Slot <slot number>, high temperature (<measured
temperature>).
Probable
Indicates that the temperature of this blade has risen above the warning threshold.
Cause
Recommended
Run the fanShow command to verify all the fans are working properly.
Action
Make sure that the area is well ventilated and that the room temperature is within operational range of
your switch. Refer to the hardware reference manual for your switch for the operational temperature
range.
Severity
WARNING
HIL-1502
Message
<timestamp>, [HIL-1502], <sequence-number>, FFDC, CRITICAL,
<system-name>, Slot <slot number>, high temperature (<measured
temperature>). Unit will be shut down in 2 minutes if temperature
remains high.
Probable
Indicates that the temperature of this blade has risen above the critical threshold. This usually follows a
Cause
high-temperature message.
Recommended
Run the fanShow command to verify all the fans are working properly.
Action
28-12