Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 387

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

RPCD System Messages
RPCD-1001
Message
<timestamp>, [RPCD-1001], <sequence-number>,, WARNING, <system-
name>, Authentication Error: client \"<IP address>\" has bad
credentials: <bad user name and password pair>
Probable
Indicates that an authentication error was reported. The specified client IP address has faulty
Cause
credentials.
Recommended
Enter the correct user name and password from the Fabric Access API host.
Action
Severity
WARNING
RPCD-1002
Message
<timestamp>, [RPCD-1002], <sequence-number>,, WARNING, <system-
name>, Missing certificate file. Secure RPCd is disabled.
Probable
Indicates that an SSL certificate is missing.
Cause
Recommended
To enable RPCD in Secure mode, install a valid SSL certificate on the switch.
Action
Severity
WARNING
RPCD-1003
Message
<timestamp>, [RPCD-1003], <sequence-number>,, WARNING, <system-
name>, Permission denied accessing certificate file. Secure RPCd is
disabled.
Fabric OS Message Reference
Publication Number: 53-1000242-01
Chapter
55
55-1

Advertisement

Table of Contents
loading

Table of Contents