36
ISNS-1003
ISNS-1003
Message
<timestamp>, [ISNS-1003], <sequence-number>,, INFO, <system-name>,
Peering with external iSNS server is disabled.
Probable
Indicates that the IP address of iSNS server is set to zero, so peering is disabled.
Cause
Recommended
If you want to enable the iSNS server to a different value, use the isnscCfg command; otherwise, no
Action
action is required.
Severity
INFO
ISNS-1004
Message
<timestamp>, [ISNS-1004], <sequence-number>,, WARNING, <system-
name>, Timeout refreshing iSNS database with iSNS server <iSNS
server IP address> slot/port <Slot number>/<Port number> Reg-Period
<Registration-Period in seconds>.
Probable
Indicates that the iSNS client failed to receive a successful response for a DevAttrQry within the
Cause
specified Registration-Period.
Recommended
Verify the connection of the iSNS server to the slot/port.
Action
Severity
WARNING
ISNS-1005
Message
<timestamp>, [ISNS-1005], <sequence-number>,, INFO, <system-name>,
User request re-register with external iSNS server <iSNS server IP
address> slot/port <Slot number>/<Port number>.
Probable
Indicates that the user has requested a re-register with the specified external iSNS server.
Cause
Recommended
No action is required.
Action
Severity
INFO