Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 354

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

44
MS-1021
Probable
MS failed while initializing the specified action.
Cause
The following actions might be displayed:
<while writing to ms_els_q>
MS is unable to write a message to the MS Extended Link Service Queue.
<while inserting timer to timer list>
MS is unable to add a timer to a resource.
Recommended
This message is often transitory.
Action
If the message persists, check the available memory on the switch using memShow.
Severity
ERROR
MS-1021
Message
<timestamp>, [MS-1021], <sequence-number>,, ERROR, <system-name>,
MS WARMBOOT failure(FSS_MS_WARMINIT failed. Reason=<failure
reason>)
Probable
Indicates that the FSS warm recovery failed during WARM INIT phase of a reboot.
Cause
Recommended
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
Action
supportSave command and contact your switch service provider.
Severity
ERROR
MS-1022
Message
<timestamp>, [MS-1022], <sequence-number>,, INFO, <system-name>,
Management Server Platform Service <Activated or Deactivated>
Probable
Indicates that Management Server Platform Service is being activated or deactivated.
Cause
Recommended
No action is required.
Action
Severity
INFO
44-4
Fabric OS Message Reference
Publication Number: 53-1000242-01

Advertisement

Table of Contents
loading

Table of Contents