Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 91

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

AUTH-1038
Message
<timestamp>, [AUTH-1038], <sequence-number>,, ERROR, <system-name>,
Failed to retrieve certificate during <authentication phase>: port
<port number>
Probable
Indicates that the PKI certificate is not installed properly.
Cause
Recommended
Reinstall the PKI certificate, using the pkiCreate command.
Action
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
ERROR
Fabric OS Message Reference
Publication Number: 53-1000242-01
2
AUTH-1038
2-13

Advertisement