26
HAM-1004
HAM-1004
Message
<timestamp>, [HAM-1004], <sequence-number>,, INFO, <system-name>,
Processor rebooted - <Reboot Reason>
Probable
This message records switch processor reboot reasons that were initiated by the user or the switch
Cause
errors. The switch reboots can be initiated by the firmwareDownload, fastBoot, haFailover, and
reboot commands. Some examples of errors that might initiate this message are hardware errors,
software errors, compact flash errors, or memory errors. The reboot reasons can be any of the
following:
Hafailover
Unknown
Fastboot
Giveup Master:SYSM
CP Faulty:SYSM
FirmwareDownload
ConfigDownload:MS
ChangeWWN:EM
Reboot:WebTool
Fastboot:WebTool
Software Fault:Software Watchdog
Software Fault:Kernel Panic
Software Fault:ASSERT
Reboot:SNMP
Fastboot:SNMP
Reboot
Chassis Config
Reboot:API
Reboot:HAM
EMFault:EM
Recommended
Check the error log on both CPs for additional messages that might indicate the reason for the reboot.
Action
Severity
INFO
26-2