55
RPCD-1004
Probable
Indicates that the SSL certificate file configured on the switch could not be accessed because root did
Cause
not have read-level access.
Recommended
Change the file system access level for the certificate file to have root read-level access.
Action
Severity
WARNING
RPCD-1004
Message
<timestamp>, [RPCD-1004], <sequence-number>,, WARNING, <system-
name>, Invalid certificate file. Secure RPCd is disabled.
Probable
Indicates that the SSL certificate file has been corrupted.
Cause
Recommended
To enable RPCD in Secure mode, install a valid SSL certificate the switch.
Action
Severity
WARNING
RPCD-1005
Message
<timestamp>, [RPCD-1005], <sequence-number>,, WARNING, <system-
name>, Missing private key file. Secure RPCd is disabled.
Probable
Indicates that the private key file is missing.
Cause
Recommended
Run the pkiCreate command to install a valid private key file.
Action
Severity
WARNING
RPCD-1006
Message
<timestamp>, [RPCD-1006], <sequence-number>,, WARNING, <system-
name>, Permission denied accessing private key file. Secure RPCd is
disabled.
Probable
Indicates that the private key file configured on the switch could not be accessed because root did not
Cause
have read-level access.
55-2
Fabric OS Message Reference