Message
<timestamp>, [SEC-1080], <sequence-number>,, ERROR, <system-name>,
Operation denied. Please, use secModeEnable command.
Probable
Indicates that there has been a corruption during the distribution of the security database. This can only
Cause
occur when the primary FCS is distributing the security database to the other switches in the fabric and
local validation finds that there is an error in the security database. This is a rare occurrence.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be
Action
in the ready state. If a switch is in the error state, the database might not be correctly updated for that
specific switch.
Severity
ERROR
SEC-1081
Message
<timestamp>, [SEC-1081], <sequence-number>,, ERROR, <system-name>,
Entered a name for a DCC policy ID that was not unique.
Probable
Indicates that the DCC policy name given in the secPolicyCreate command was the same as another
Cause
DCC policy.
Recommended
Make sure that the DCC policy name has a unique alpha-numeric string, and run the secPolicyCreate
Action
command again.
Severity
ERROR
SEC-1082
Message
<timestamp>, [SEC-1082], <sequence-number>,, ERROR, <system-name>,
Failed to create <policy name> policy.
Probable
Indicates that the security policy was not created due to faulty input or low resources.
Cause
Recommended
Use proper syntax when creating policies. If the security database is too large, you must delete other
Action
members within the database before adding new members to a policy.
Severity
ERROR