25
FW-1433
Recommended
Replace the faulty WWN card.
Action
Severity
WARNING
FW-1433
Message
<timestamp>, [FW-1433], <sequence-number>,, WARNING, <system-name>,
Switch status change contributing factor CP: CP non-redundant.
Probable
Indicates that the switch status is not in a healthy state. This occurred because the number of faulty CPs
Cause
is greater than or equal to the policy set by the switchStatusPolicySet command. The CPs are non-
redundant.
If you power cycle a SilkWorm 24000 chassis in dual-domain configuration, and then reset the micro-
switch of the active CP before the heartbeat is up, this will cause both CPs to come up in a non-
redundant state.
Recommended
Run the firmwareShow command to verify that both CPs have compatible firmware levels. Run the
Action
firmwareDownload command to install the same level of firmware to both CPs. Replace any faulty
CPs.
If you reset the micro-switch (the latch on the CP blade) on the active CP before the heartbeat was up on
a power cycle, and the CPs came up non-redundant, then you should reboot the CPs again to clear the
problem.
Severity
WARNING
FW-1434
Message
<timestamp>, [FW-1434], <sequence-number>,, WARNING, <system-name>,
Switch status change contributing factor Blade: <Number Bad> blade
failures.
Probable
Indicates that the switch status is not in a healthy state. This occurred because the number of blade
Cause
failures is greater than or equal to the policy set by the switchStatusPolicySet command.
Recommended
Replace the faulty blade.
Action
Severity
WARNING
25-80
Fabric OS Message Reference
Publication Number: 53-1000242-01