If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
EM-1017
Message
<timestamp>, [EM-1017], <sequence-number>,, WARNING, <system-name>,
Uncommitted WWN change detected. Cold reboot required.
Probable
Indicates that a user did not commit a changed WWN value prior executing a reboot, power cycle, or
Cause
firmwareDownload operation.
Recommended
Change and commit the new WWN value.
Action
Severity
WARNING
EM-1018
Message
<timestamp>, [EM-1018], <sequence-number>, FFDC, CRITICAL, <system-
name>, CP blade in slot <slot number> failed to retrieve current
chassis type (<detailed fault descriptor>/<PLACE HOLDER>/0x<PLACE
HOLDER>).
Probable
Indicates that there was a failure to read the chassis type from the system.
Cause
Recommended
Verify that the CP blade is operational and is properly seated in its slot.
Action
Severity
CRITICAL
EM-1019
Message
<timestamp>, [EM-1019], <sequence-number>,, WARNING, <system-name>,
Current chassis configuration option (<Chassis config option
currently in effect>) is not compatible with standby firmware
version (Pre 4.4), cannot allow HA Sync.
Probable
Indicates that the current chassisConfig option is not supported by the firmware on the standby CP. This
Cause
is true even if the standby comes up and appears to be operational. HA synchronization of the CPs will
not be allowed.