SYSC System Messages
SYSC-1001
Message
<timestamp>, [SYSC-1001], <sequence-number>, FFDC, CRITICAL,
<system-name>, Failed to run <Name of program that could not be run
(string)>:<System internal error message (string)>
Probable
Indicates that during the boot sequence, one of the programs would not run on the system.
Cause
Recommended
If the message is reported during a reboot after new firmware has been loaded, try reloading the
Action
firmware using the firmwareDownload command.
If the message persists, there might be a conflict between the two versions of firmware or the
nonvolatile storage might be corrupted. Run supportFtp (as needed) to set up automatic FTP transfers;
then run the supportSave command and contact your switch service provider.
Severity
CRITICAL
SYSC-1002
Message
<timestamp>, [SYSC-1002], <sequence-number>, FFDC, CRITICAL,
<system-name>, Switch bring-up timed out
Probable
Indicates that the system timed out during a reboot or failover sequence, waiting for one or more
Cause
programs to register with system services or to fail over to active status.
Recommended
The switch is in an inconsistent state and can be corrected only by a reboot or power cycle. Before
Action
rebooting the chassis, record the firmware version on the switch (or CP) and run the haDump
command. If this is a dual-CP switch, then gather the output from the CP in which this log message
appeared.
Severity
CRITICAL
Fabric OS Message Reference
Publication Number: 53-1000242-01