Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 398

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

58
SEC-1016
Recommended
Check for unauthorized access to the switch through the telnet connection.
Action
Severity
INFO
SEC-1016
Message
<timestamp>, [SEC-1016], <sequence-number>,, INFO, <system-name>,
Security violation: Unauthorized host with IP address <IP address
of the violating host> tries to establish SSH connection.
Probable
Indicates that a security violation was reported. The IP address of the unauthorized host is displayed in
Cause
the message.
Recommended
Check for unauthorized access to the switch through the SSH connection.
Action
Severity
INFO
SEC-1022
Message
<timestamp>, [SEC-1022], <sequence-number>,, WARNING, <system-
name>, Failed to <operation> PKI objects.
Probable
Indicates that the security server failed to generate or validate either the public or private key pair or the
Cause
CSR.
Recommended
Run the pkiShow command and verify that all PKI objects exist on the switch. If the private key does
Action
not exist, follow the steps for re-creating PKI objects, outlined in the Secure Fabric OS Administrator's
Guide. If a certificate does not exist or is invalid, install the certificate by following the field upgrade
process.
Severity
WARNING
SEC-1024
Message
<timestamp>, [SEC-1024], <sequence-number>,, INFO, <system-name>,
The <DB name> security database is too large to fit in flash.
Probable
Indicates that the size of the security database is too large for the flash memory. The size of the security
Cause
database increases with the number of entries in each policy.
Recommended
Reduce the size of the security database by reducing the number of entries within each policy.
Action
58-4
Fabric OS Message Reference
Publication Number: 53-1000242-01