FW-1043
Message
<timestamp>, [FW-1043], <sequence-number>,, WARNING, <system-name>,
<Label>, is above high boundary(High=<High value>, Low=<Low
value>). Current value is <Value> <Unit>.
Probable
Indicates that the transmit power value of the SFP has risen above the high boundary. The transmit
Cause
performance area measures the amount of outgoing laser to help you determine if the SFP is in good
working condition or not. If the counter often exceeds the threshold, the SFP is deteriorating.
Recommended
Replace the SFP.
Action
Severity
WARNING
FW-1044
Message
<timestamp>, [FW-1044], <sequence-number>,, INFO, <system-name>,
<Label>, is between high and low boundaries(High=<High value>,
Low=<Low value>). Current value is <Value> <Unit>.
Probable
Indicates that the transmit power value of the SFP has changed from a value outside of the acceptable
Cause
range to a value within the acceptable range. The transmit performance area measures the amount of
outgoing laser to help you determine if the SFP is in good working condition or not. If the counter often
exceeds the threshold, the SFP is deteriorating.
Recommended
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
Action
installation.
Severity
INFO
FW-1045
Message
<timestamp>, [FW-1045], <sequence-number>,, INFO, <system-name>,
<Label>, value has changed(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
Probable
Indicates that the value of the SFP voltage has changed. If the supplied voltage of the SFP transceiver is
Cause
outside of the normal range, this might indicate a hardware failure.
Recommended
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
Action
installation. Frequent messages indicate that you must replace the SFP.
Fabric OS Message Reference
Publication Number: 53-1000242-01
25
FW-1043
25-9