FCR-1062
Message
<timestamp>, [FCR-1062], <sequence-number>,, INFO, <system-name>,
Port <port number> disabled, system only supports <maximum ports>
ports.
Probable
Indicates that the maximum number of supported ports was exceeded. To enable this port, disable any
Cause
other operational port then re-enable the port.
Recommended
No action is required.
Action
Severity
INFO
FCR-1063
Message
<timestamp>, [FCR-1063], <sequence-number>,, INFO, <system-name>,
Fabric <fabric ID> for switch with domain ID: <domain ID> mismatches
with local fabric ID <local fabric ID>.
Probable
Indicates that the fabric ID of the switch does not match with the local switch.
Cause
Recommended
Run the switchShow command to display the fabric ID. Change the fabric ID to match on both ends by
Action
modifying either the local or remote host using the fcrConfigure command.
Severity
INFO
FCR-1064
Message
<timestamp>, [FCR-1064], <sequence-number>,, ERROR, <system-name>,
Fabric ID of backbone FC-Routers mismatch or overlap.
Probable
Indicates that either the a backbone fabric split and both are connected to common edge fabrics, or the
Cause
fabric ID of two backbone fabrics, which are connected to an edge fabric, are the same.
Recommended
If the backbone fabric split, merge the fabrics.
Action
If two (or more) backbone fabrics have the same IDs, make the fabric IDs unique using fcrConfigure
command.
Severity
ERROR