Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 111

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

Severity
WARNING
BM-1006
Message
<timestamp>, [BM-1006], <sequence-number>,, INFO, <system-name>,
Blade is not configured. Persistently disabling all ports for blade
in slot <Slot number>
Probable
The policy of the specified blade is to persistently disable all ports the first time the blade is detected, so
Cause
either:
The blade was detected for the first time in this slot
The blade was configured under a different mode
Recommended
Configure the blade and persistently enable the ports.
Action
Severity
INFO
BM-1007
Message
<timestamp>, [BM-1007], <sequence-number>,, INFO, <system-name>,
Clearing EX/VEX port configuration for all ports for blade in slot
<Slot number>
Probable
The new blade requires these port configurations to be cleared. The blade was detected for the first time
Cause
after an FR4-18i was previously configured in the same slot.
Recommended
No action is required.
Action
Severity
INFO
BM-1008
Message
<timestamp>, [BM-1008], <sequence-number>,, WARNING, <system-name>,
Download of blade firmware failed for blade in slot <slot>. Reissue
firmwaredownload to recover.
Probable
The automatic firmware upgrade on the blade has failed because the blade firmware version was
Cause
detected to be different from CP firmware version due to a firmware upgrade.
Recommended
Issue the firmwareDownload command to recover the blade.