3
BL-1024
Recommended
Reboot or power cycle the blade.
Action
If the message persists, replace the blade.
Severity
CRITICAL
BL-1024
Message
<timestamp>, [BL-1024], <sequence-number>,, INFO, <system-name>,
All ports on the blade in slot <slot number> will be reset as part
of the firmware upgrade.
Probable
Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the
Cause
cold upgrade. As part of the upgrade, all datapath elements were reset.
Recommended
No action is required.
Action
Severity
INFO
BL-1025
Message
<timestamp>, [BL-1025], <sequence-number>,, INFO, <system-name>,
All GigE/FCIP ports on the blade in slot <slot number> will be reset
as part of the firmware upgrade.
Probable
Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the
Cause
cold upgrade. As part of the upgrade, all GigE/FCIP data elements were reset.
Recommended
No action is required.
Action
Severity
INFO
BL-1026
Message
<timestamp>, [BL-1026], <sequence-number>,, CRITICAL, <system-
name>, Internal port offline during warm recovery, state <port
state> (0x<port ID>)
Probable
Indicates that an internal port went offline during the warm recovery of the switch.The switch will
Cause
reboot and start a cold recovery.
3-10
Fabric OS Message Reference
Publication Number: 53-1000242-01