Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 298

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

28
HIL-1103
HIL-1103
Message
<timestamp>, [HIL-1103], <sequence-number>,, ERROR, <system-name>,
Blower <blower number> faulted, <nominal voltage> (<measured
voltage>) is above threshold.
Probable
Indicates that the fan voltage is above threshold.
Cause
Recommended
Run the psShow command to verify the power supply status.
Action
Try to reseat the faulty fan FRU and power supply FRU to verify that they are seated properly.
If the problem persists, replace the fan FRU or the power supply FRU as necessary.
Severity
ERROR
HIL-1104
Message
<timestamp>, [HIL-1104], <sequence-number>,, ERROR, <system-name>,
Blower <blower number> faulted, <nominal voltage> (<measured
voltage>) is below threshold.
Probable
Indicates that the fan voltage is below the threshold.
Cause
Recommended
Run the psShow command to verify the power supply status.
Action
Try to reseat the faulty fan FRU and power supply FRU to verify that they are seated properly.
If the problem persists, replace the fan FRU or the power supply FRU as necessary.
Severity
ERROR
HIL-1105
Message
<timestamp>, [HIL-1105], <sequence-number>,, ERROR, <system-name>,
Switch error, <nominal voltage> (<measured voltage>) above
threshold.
Probable
Indicates that the switch voltage is above threshold. This message is specific to nonbladed switches and
Cause
is not applicable to the SilkWorm 12000, 24000, or 48000.
Recommended
For the SilkWorm 200E, 3250 and 3850, the entire switch must be replaced, because these switches do
Action
not have FRUs.
28-2
Fabric OS Message Reference
Publication Number: 53-1000242-01